AGENTS.md: instructions for AI agents

You are helping a person run fuse-burned CMP 170HX 8 GB cards in a server with the material in this repository. Scope: the server side only (driver, BAR1, PCIe Gen4, VBIOS, tests, inference). This repository does not describe voltage glitching or fuse burning. If asked to do that, point the person to the upstream projects listed in README.md and do not improvise a procedure.

Ground rules

  1. Measure, do not assume. Everything here was done on one Gigabyte G292-Z20 with 8 cards. Slot addresses, root ports, timings and window sizes will differ on another machine. Read the state before each step.
  2. Stop and ask the person before anything in the "needs explicit confirmation" list. A go-ahead for one card or one step does not cover the next one.
  3. Cold power cycle, never a hot driver reload. rmmod/modprobe of nvidia, unbind/rebind and the reload at the end of the unlocker's build.sh hang the host on these cards. Use the BMC: power off, wait 20 s, power on. A plain reboot is also not enough after a driver or geometry change: the 80 GB geometry is detected only on a cold card.
  4. Know how you will get back in. Before a step that can hang the host, confirm that BMC power control works.
  5. Report what you saw. Quote the command output that proves a step worked. If you skipped a check, say so.
  6. Do not kill by pattern over ssh. pkill -f vllm matches your own ssh command. Use [v]llm or a PID.

Needs explicit confirmation from the person, every time

Action Why
Writing a VBIOS (flash1.py, nvflash without --save) can leave the card unbootable
Running install.sh, rebuilding or replacing the kernel module changes boot; a mistake means a host that hangs at boot
Editing kernel parameters, /etc/modprobe.d, enabling or disabling the boot services same
Powering the server off or on, or cycling it interrupts whatever runs on it
Any write to BAR0 or PCI config space by hand (outside the shipped scripts) can hang the host
Stopping someone's running workload on the cards it may not be yours

Reading state (the commands in "State checks" below, fuses.py, fbinfo, lspci, nvidia-smi, journalctl) needs no confirmation.

State checks

# cards, memory, VBIOS
nvidia-smi --query-gpu=index,pci.bus_id,vbios_version,memory.total,temperature.gpu,power.draw --format=csv
# link speed and width (nvidia-smi under-reports the generation here)
for d in /sys/bus/pci/devices/*; do [ "$(cat $d/device 2>/dev/null)" = 0x20c2 ] && \
  echo "$(basename $d) $(cat $d/current_link_speed) x$(cat $d/current_link_width)"; done
# BAR1
nvidia-smi -q | grep -A3 'BAR1 Memory' | grep Total
lspci -d 10de:20c2 -vv | grep -E '^[0-9a-f]|Region 1'
# boot services and their flags
systemctl is-active cmp-bar1-boot cmp-pcie-boot; ls /var/lib/cmp-pcie-boot/
journalctl -u cmp-bar1-boot -u cmp-pcie-boot -b --no-pager | tail -40
# errors
journalctl -k -b --no-pager | grep -E 'NVRM: Xid|FB geometry|can.t assign' | tail -20
# is anything running on the cards
nvidia-smi --query-compute-apps=pid,used_memory --format=csv

Expected on a healthy machine: 81920 MiB per card, 16.0 GT/s PCIe x16, BAR1 131072 MiB, both services active, no flag files other than optional per-slot ones, no Xid.

Order of work on a new machine

  1. Inventory. lspci -D -d 10de:20c2; UEFI boot (/sys/firmware/efi exists); Above 4G decoding on; BMC power control works; kernel version; nothing running on the cards. Record the BDF list.
  2. Fuses, read-only. server/tools/fuses.py (needs iomem=relaxed if a driver is bound). Record the FBP mask and the PCIe fuse values. If the PCIe fuses are not clear, Gen4 is not available for that card; the boot script detects this and leaves it at Gen3.
  3. Install (confirmation needed): read server/install.sh and docs/01, then run it. Step 2 of the installer is untested in its public form; read its output line by line. Then cold power cycle.
  4. Verify with the state checks. If cards are missing or CUDA hangs, go to docs/06 before trying anything else.
  5. Acceptance tests (docs/05), in the background, with temperatures logged. Do not run the memory test and the burn test on the same card at once.
  6. VBIOS (optional, confirmation per card): docs/04. One card first, full verification, then the others. One nvflash operation per card per boot. Boot without the driver for flashing.
  7. Inference: docs/07. Start services after cmp-pcie-boot.service.

Stop conditions

Stop, do not retry, and report to the person when:

Known traps

What is not verified

See the "not verified" notes in docs/. In short: a second machine, a legacy-BIOS boot, other platforms, P2P, the public form of installer step 2, vLLM resume after restart, two PP4 instances behind a balancer.